Back

Information for ruling 600002442

This section is Advance Tariff Ruling

Start date
29 Nov 2021
Expiry date
28 Nov 2024
Description
Fire Alarm System Transmitter/Dialer Module, for use with the NFU-7000 Panel, capable of transmitting alarm, supervisory and fault information on two telephone lines to an external monitoring facility. The Module comprises a populated PCB (Printed Circuit Board) with user interface connectors, LEDS on the front of the product for indication of output status. The Module mounts inside the NFU-7000 and acts as a slave interface unit, taking its control commands from the primary addressable fire alarm panel and reporting activation & fault conditions to external monitoring station. It does not contain an integral sounder or recording device. Packaged singularly in a cardboard box or within a larger cardboard box containing 10 or 100 units.
Keywords
PART OF FIRE ALARMS FOR FAULT DETECTION ALARM EQUIPMENT PARTS SIGNALLING EQUIPMENT
Justification
Classification has been determined in accordance with the following: - General Interpretative Rules (GIR)s: GIR 1 has been used to classify this product by the terms of heading 8531 - Electric sound or visual signalling apparatus (for example, bells, sirens, indicator panels, burglar or fire alarms), other than those of heading 8512 or 8530 GIR 5 (b) has been used to identify the type of packaging. GIR 6 has been used to classify the goods to subheading level 853190 - Parts Also classified in accordance with: General Section XVI note 2 (a) Harmonised System Explanatory Notes (HSENS) to heading 8531.90 refers